Model | Overall dimensions (LxWxD) mm | Work area size (LxW) mm | Air outlet rated air speed (m/s) | Work area cleanliness (grade) | Noise (dB) | Illumination (Lx) | Power (KW) |
LUFH12-120.60* | 1200×600×600 | 1200×600 | 0.45±20% | A | 65 ~ 75 | 300 ~ 500 | 0.3 |
LUFH16-100.100* | 1000×1000×600 | 1000×1000 | 0.45 | ||||
LUFH24-120.120* | 1200×1200×600 | 1200×1200 | 0.6 | ||||
LUFH32-200.100* | 2000×1000×600 | 2000×1000 | 0.9 | ||||
LUFH48-120.120* | 1200×1200×600 | 1200×1200 | 1.2 | ||||
LUFH65-200.200* | 2000×2000×600 | 2000×1000 | 1.8 | ||||
Note: The specifications listed in the table are for customer reference only. Most Class A unidirectional laminar flow hoods are designed and manufactured according to the User Requirement Specification (URS) of customers. | |||||||
Model | Overall dimensions (L×W×D) mm | Work area size (L×W×H) mm | Air outlet rated air speed (m/s) | Work area cleanliness (grade) | Noise (dB) | Illumination (Lx) | Power (KW) |
LUFT8-120.60 | 800×650×1800 | 720×600×750 | 0.45±20% | A | 65 ~ 75 | 300 ~ 500 | 0.18 |
LUFT10-100.100* | 1000×650×1800 | 920×600×750 | 0.18 | ||||
LUFT15-120.120* | 1200×750×1800 | 1120×700×750 | 0.25 | ||||
LUFT19-200.100* | 1400×850×1800 | 1320×800×750 | 0.36 | ||||
Note:The specifications listed in the table are only for reference. Class A unidirectional flow transfer trolleys can be designed and manufactured according to URS of customers. |
Model | Overall dimensions (L×W×D) mm | Work area size (L×W) mm | Work area cleanliness (grade) | Air outlet rated air speed (m/s) | Noise (dB) | Illumination (Lx) |
LRABS***** | Custom | Custom | A | 0.45±20% | 65 | 300 |
Note:Open Rabs has no standard products, which are designed and manufactured according to urs of customers | ||||||
Model | Overall dimensions (L×W×D) mm | Rated air volume (m³/h) / speed (m/s) | Initial Resistance (Pa) | Noise (dB) | Power (kW) | |
(H14) Counting efficiency 0.3μm≥99.995% | (H15) Counting efficiency 0.1μm≥99.9995% | |||||
LFFU10-117.57 | 1170×570×350 | 1000 / 0.45 | 120 | 200 | 57 | 0.18 |
LFFU15-117.87 | 1170×870×350 | 1500 / 0.45 | 60 | 0.25 | ||
LFFU20-117.117 | 1170×1170×350 | 2000 / 0.45 | 63 | 0.37 | ||
Note:The thickness of the H14 high-efficiency filter in the table is 90mm,and that of the U15 ultra-high efficiency filter is 70mm. |
Model | Overall Dimensions (L×W×D) mm | Work-Area Size (L×W×H) mm | Work area cleanliness (grade) | Air-Outlet Rated Speed (m/s) | Noise (dB) | Ozone Concentration (ppm) | UV Sterilization Lamp Power (W) | Power Supply (kW) |
LCTW4-50.50.50 | 700 × 1000 × 550 | 500 × 500 × 500 | A | 0.45 ±20 % | 65 | 20-50 According to the configuration | 8 | 0.15 |
LCTW6-60.60.60 | 800 × 1100 × 650 | 600 × 600 × 600 | 15 | 0.15 | ||||
LCTW8-70.70.70 | 900 × 1200 × 750 | 700 × 700 × 700 | 15 | 0.15 | ||||
Note:The specifications listed in the table are only for reference.The products can be designed and manufactured according to URS of customers. | ||||||||
Model | Overall Dimensions (L×W×D) mm | Work-Area Size (L×W×H) mm | Work area cleanliness (grade) | Air-Outlet Rated Speed (m/s) | Noise (dB) | IIlumination (Lx) | Power Supply (kW) | |
LWR12-120.60* | 1 300 × 1 200 × 2 570 | 1 200 × 600 × 2 000 | with the background area | 0.45 ±20 % | 75 | 300 ~ 500 | 0.3 | |
LWR16-100.100* | 1 600 × 1 800 × 2 570 | 1 500 × 1 200 × 2 000 | 0.45 | |||||
LWR24-120.120* | 2 100 × 2 700 × 2 570 | 2 000 × 2 000 × 2 000 | 0.6 | |||||
LWR32-200.100* | 3 100 × 2 700 × 2 570 | 3 000 × 2 000 × 2 000 | 0.9 | |||||
LWR48-120.120* | 4 100 × 3 200 × 2 570 | 4 000 × 2 500 × 2 000 | 1.2 | |||||
Note:The specifications listed in the table are only for reference.The products can be designed and manufactured according to URS of customers. |
Model | Overall dimensions (LxWxD) | Work area size (LxW) | Air outlet cleanliness grade | Nozzle rated air speed (m/s) | Noise (dB) | Nozzle quantity | High-efficiency size (LxWxD) |
LASRS-120.100 | 1200×1000×2100 | 750×900×1950 | A | 25 | 75 | 6 | 610×610×90×1 |
ZLASR10-150.100 | 1500×1000×2100 | 800×900×1950 | 12 | 610×610×90×2 | |||
ZLASR20-150.200 | 1500×2000×2100 | 800×1900×1950 | 24 | 610×610×90×4 | |||
3LASR30-200.200 | 2500×2000×2350 | 1800×1900×650 | 36 | 610×610×90×6 | |||
Note:Air shower rooms and air shower passages with specifications not listed in the table can be manufactured according to customer requirements. | |||||||
Model | Overall dimensions (LxWxD) | Work area size (LxW) | Nominal volume (L) | Work area cleanliness (grade) | Sterilization efficacy | Power (KW) | |
LATM500-70.70.100 | 1400×1000×1650 | 700×700×1000 | 500 | A/B | 6-log | 3 | |
LATM1000-90.100.110 | 1600×1300×1750 | 900×1000×1100 | 1000 | 3 | |||
LATM1500-100.120.120 | 1700×1500×1850 | 1000×1200×1200 | 1500 | 3 | |||
Note:The specifications listed in the table are only for reference.The products can be designed and manufactured according to URS of customers. | |||||||
Model | Overall dimensions (LxWxD) | Work area size (LxW) | Cleanliness grade (grade) | Air outlet rated air speed (m/s) | Noise (dB) | High-efficiency size (LxWxD) | |
LCW10V-97.72D | 970×720×1600 | 810×700×500 | 100(A) | 0.45±20% | 65 | 760×610×70×1 | |
LCW15V-145.72D | 1450×720×1600 | 1290×700×500 | 610×610×70×2 | ||||
LCW10H-97.82C | 970×825×1500 | 810×650×600 | 760×610×70×1 | ||||
LCW15H-140.82C | 1400×825×1500 | 1290×650×650 | 610×610×70×2 | ||||
Note:Clean benches with specifications not listed in the table can be manufactured according to customer requirements. |